Skip to content

Fix - Expose Splunk HEC sink sent-bytes metrics from sink start - #187

Open
nafiul-s1 wants to merge 1 commit into
masterfrom
fix_hec_sink_sent_bytes_metrics_from_start
Open

nafiul-s1 wants to merge 1 commit into
masterfrom
fix_hec_sink_sent_bytes_metrics_from_start

Conversation

@nafiul-s1

Copy link
Copy Markdown

A sink showed no component_sent_* series until its first successful request, and component_sent_bytes_total was deleted again after expire_metrics_secs of idle time, because emit!(EndpointBytesSent) creates the counter and drops the handle on every call. Sources do not have this problem: their EventsSent handle is registered at build and held. The manager's sink "no data" alert reads
vector_component_sent_bytes_total, so it could not fire for a sink that had never sent anything.

  • BytesSent gets an optional endpoint label (like EventsSent's optional output). Existing BytesSent::from(Protocol::X) users get endpoint: None and produce the same series as before.
  • Driver gets .endpoint(..) next to .protocol(..); it already registers and holds BytesSent at start when a protocol is given.
  • The Splunk HEC logs and metrics sinks compute (protocol, endpoint) once at build (bytes_sent_labels, built the same way a request builds them) and pass them to the driver, so the driver holds the exact series that emit!(EndpointBytesSent) counts into.
  • Driver also registers and holds the untagged component_sent_events_total and component_sent_event_bytes_total series at start.

Result: the HEC sink exposes component_sent_bytes_total{protocol,endpoint} and the events counters at 0 from startup, and they are not expired while the sink runs. emit!(EndpointBytesSent) still does the counting.

Known limits: a config reload while the sink was idle past expire_metrics_secs still resets the counters (the old component is shut down before the new one is built); other sinks are unchanged.

Tested: cargo test --lib sinks::splunk_hec (105 passed), and manual runs with a fake HEC endpoint (nothing sent, 5 events then idle past expiry).

A sink showed no `component_sent_*` series until its first successful
request, and `component_sent_bytes_total` was deleted again after
`expire_metrics_secs` of idle time, because `emit!(EndpointBytesSent)`
creates the counter and drops the handle on every call. Sources do not
have this problem: their `EventsSent` handle is registered at build and
held. The manager's sink "no data" alert reads
`vector_component_sent_bytes_total`, so it could not fire for a sink that
had never sent anything.

- `BytesSent` gets an optional `endpoint` label (like `EventsSent`'s
  optional `output`). Existing `BytesSent::from(Protocol::X)` users get
  `endpoint: None` and produce the same series as before.
- `Driver` gets `.endpoint(..)` next to `.protocol(..)`; it already
  registers and holds `BytesSent` at start when a protocol is given.
- The Splunk HEC logs and metrics sinks compute `(protocol, endpoint)`
  once at build (`bytes_sent_labels`, built the same way a request builds
  them) and pass them to the driver, so the driver holds the exact series
  that `emit!(EndpointBytesSent)` counts into.
- `Driver` also registers and holds the untagged `component_sent_events_total`
  and `component_sent_event_bytes_total` series at start.

Result: the HEC sink exposes `component_sent_bytes_total{protocol,endpoint}`
and the events counters at 0 from startup, and they are not expired while
the sink runs. `emit!(EndpointBytesSent)` still does the counting.

Known limits: a config reload while the sink was idle past
`expire_metrics_secs` still resets the counters (the old component is shut
down before the new one is built); other sinks are unchanged.

Tested: `cargo test --lib sinks::splunk_hec` (105 passed), and manual runs
with a fake HEC endpoint (nothing sent, 5 events then idle past expiry).