A "signaling accumulator" would be a useful concept for many graph algorithms where you want to keep track of whether an update has occurred in each iteration.
For example, in SSSP, we can test whether the algorithm has converged by checking whether any new updates were made to the distance vector during this iteration. Traditionally, you'd check this by performing an additional subtraction, or else otherwise checking whether the new distance vector has any new, shorter distances. Alternately, you could implement a new min operator that sets a flag if there's an update. If no update occurs, the algorithm has converged, and the algorithm can end.
bool updated_value = false;
auto signaling_min = [&](auto&& a, auto&& b) {
auto min = grb::min{}(a, b);
if (min != a) {
updated_value = true;
return min;
};
auto update = grb::multiply(grb::transpose(a), dist,
grb::min{}, grb::plus{},
grb::full_vector_mask{});
auto dist2 = grb::ewise_union(dist, update, signaling_min);
if (!updated_value) {
break;
}
For GraphBLAS C++ 2.0, I would propose implementing a "signaling op" wrapper that indicates whether an update occurs when accumulating.
// Proposal for signal APIbool update
grb::signal min(grb::min{}, update);
template <typename Fn, typename Flag>
structsignal {
operator()(auto&& a, auto&& b) {
auto c = fn_(a, b);
if (c == a) {
flag_ = true;
}
return c;
}
Flag& flag_;
Fn fn_;
};
It would be difficult to implement this as the monoid of a semiring, inside a matrix multiply. It's a barrier for getting good performance in the parallel case. It's not clear from the example, but it looks like 'update' is being computed by the matrix-vector multiply. But your example only uses signaling_min in the ewise operation. How is it being computed by the matrix-vector multiply?
In a matrix-vector multiply, you'd likely only ever want to use a signaling accumulator for the accumulator, not in the monoid. The purpose is to figure out whether c changed in c += a*b.
Take SSSP. Suppose you're doing the following matrix-vector multiply (C API syntax now), where dist is a vector holding the current shortest distance to each vertex, and graph holds your graph.
dist now holds the new updated distances, if there are any that have been updated in dist by the GrB_MIN_INT32 accumulator. But how do we know whether there were updates? Typically, you'd have to store the result in a new vector, dist2, and compare.
What I'm suggesting (for C++) is you instead could use a wrapper around GrB_MIN_INT32 that writes to a flag if a value of dist is updated. This would be an idempotent write from false to true, so in terms of thread safety, you'd only need a memory fence/barrier after the mxv, which you already need anyway. One of these "signaling" operators is fairly straightforward to implement on your own in C++ using lambdas, but a grb::signal, etc., could make this very easy.
bool update = false;
// Wrap the `grb::min` operator.// Write the value `true` to `update` if a value is updatedauto signaling_min = [&](auto&& a, auto&& b) {
auto min = grb::min{}(a, b);
if (min != a) {
update = true;
return min;
};
As I look back at my original example, I used update twice, which is probably a point of confusion. The "signal" accumulation operator should only write to a single scalar flag, from true to false, if one of the values in the output is going to be changed. It shouldn't write to a matrix or vector.
Yes, that's where I was confused and thought you were using the update flag from signaling_min in the matrix-vector multiply, which then returned it as a scalar. So the return value of "update = grb::multiply (...)" is a vector, called 'update', right?
In that case, a binary operator 'signaling_min' would be well-defined for an ewise operation, and not be hard to implement in parallel. It could also appear as the accumulator op in the matrix multiply, outside of the semiring. It would be very difficult inside a semiring, where it becomes ill-defined and gums up the implemenation particularly in the parallel case.
It would be best not to assume a global value for the boolean 'update' flag, however. That would mess up the case where multiple user-threads are each doing their own calls to an ewise operation using signaling_min.
Yes update is a vector returning from multiply. (I updated my example to use updated_value for the boolean.)
My idea was that the signaling accumulator would be a user-defined (or user-assisted op), and that users could pass in a reference to the location they want updated. (I suppose if you wanted to do this in C, you could pass in a pointer.)
Although, unfortunately, I just realized that what I outlined above is not actually sufficient. We care not only about cases in which c is accumulated into, but also cases where c had no stored value, and a new value is inserted with no accumulation.
So, unless c already has a stored value in every spot, I think we'd need some actual modification to mxv or ewise to do what's needed (at least for SSSP where the dist vector is allowed to be sparse).
perhaps a better solution would be some kind of way to tell GraphBLAS: "compute C += (stuff) and tell me if C changes at all" (where "+=" is any accumulator op). That would be more general than a signaling_min. I think it would require the accum operator to be present, at least to implement it efficiently. Then "stuff" could be anything at all, any GrB operation.
The blocking/non-blocking case would be delicate for this output flag. What if the operation was non-blocking and the computation postponed? The "update" flag would have to force a block, if it were a non-opaque scalar.
Yeah, I think this gets potentially very complicated in the mxm case. Not so much that it's a difficult thing to do, but that it's difficult to expose it in an elegant and thread-safe way.
In the ewise case, you can use the behavior we want by also checking if the number of stored values has changed in a new output vector. (e.g. in SSSP in this C++ draft impl).
However, element-wise creates a new object, and ideally you'd be able to avoid that by just using mxv.
Activity
DrTimothyAldenDavis commentedon Oct 11, 2022
It would be difficult to implement this as the monoid of a semiring, inside a matrix multiply. It's a barrier for getting good performance in the parallel case. It's not clear from the example, but it looks like 'update' is being computed by the matrix-vector multiply. But your example only uses signaling_min in the ewise operation. How is it being computed by the matrix-vector multiply?
BenBrock commentedon Oct 11, 2022
In a matrix-vector multiply, you'd likely only ever want to use a signaling accumulator for the accumulator, not in the monoid. The purpose is to figure out whether
cchanged inc += a*b.Take SSSP. Suppose you're doing the following matrix-vector multiply (C API syntax now), where
distis a vector holding the current shortest distance to each vertex, andgraphholds your graph.mxv(dist, GrB_NULL, GrB_MIN_INT32, GrB_PLUS_MIN_SEMIRING_INT32, graph, dist, GrB_TRAN);distnow holds the new updated distances, if there are any that have been updated indistby theGrB_MIN_INT32accumulator. But how do we know whether there were updates? Typically, you'd have to store the result in a new vector,dist2, and compare.What I'm suggesting (for C++) is you instead could use a wrapper around
GrB_MIN_INT32that writes to a flag if a value ofdistis updated. This would be an idempotent write fromfalsetotrue, so in terms of thread safety, you'd only need a memory fence/barrier after themxv, which you already need anyway. One of these "signaling" operators is fairly straightforward to implement on your own in C++ using lambdas, but agrb::signal, etc., could make this very easy.BenBrock commentedon Oct 11, 2022
As I look back at my original example, I used
updatetwice, which is probably a point of confusion. The "signal" accumulation operator should only write to a single scalar flag, from true to false, if one of the values in the output is going to be changed. It shouldn't write to a matrix or vector.DrTimothyAldenDavis commentedon Oct 11, 2022
Yes, that's where I was confused and thought you were using the update flag from signaling_min in the matrix-vector multiply, which then returned it as a scalar. So the return value of "update = grb::multiply (...)" is a vector, called 'update', right?
In that case, a binary operator 'signaling_min' would be well-defined for an ewise operation, and not be hard to implement in parallel. It could also appear as the accumulator op in the matrix multiply, outside of the semiring. It would be very difficult inside a semiring, where it becomes ill-defined and gums up the implemenation particularly in the parallel case.
It would be best not to assume a global value for the boolean 'update' flag, however. That would mess up the case where multiple user-threads are each doing their own calls to an ewise operation using signaling_min.
BenBrock commentedon Oct 11, 2022
Yes
updateis a vector returning frommultiply. (I updated my example to useupdated_valuefor the boolean.)My idea was that the signaling accumulator would be a user-defined (or user-assisted op), and that users could pass in a reference to the location they want updated. (I suppose if you wanted to do this in C, you could pass in a pointer.)
BenBrock commentedon Oct 11, 2022
Although, unfortunately, I just realized that what I outlined above is not actually sufficient. We care not only about cases in which
cis accumulated into, but also cases wherechad no stored value, and a new value is inserted with no accumulation.So, unless
calready has a stored value in every spot, I think we'd need some actual modification tomxvorewiseto do what's needed (at least for SSSP where thedistvector is allowed to be sparse).DrTimothyAldenDavis commentedon Oct 11, 2022
Yes, I thought about that too.
perhaps a better solution would be some kind of way to tell GraphBLAS: "compute C += (stuff) and tell me if C changes at all" (where "+=" is any accumulator op). That would be more general than a signaling_min. I think it would require the accum operator to be present, at least to implement it efficiently. Then "stuff" could be anything at all, any GrB operation.
The blocking/non-blocking case would be delicate for this output flag. What if the operation was non-blocking and the computation postponed? The "update" flag would have to force a block, if it were a non-opaque scalar.
Gets gnarly...
BenBrock commentedon Oct 12, 2022
Yeah, I think this gets potentially very complicated in the mxm case. Not so much that it's a difficult thing to do, but that it's difficult to expose it in an elegant and thread-safe way.
In the ewise case, you can use the behavior we want by also checking if the number of stored values has changed in a new output vector. (e.g. in SSSP in this C++ draft impl).
However, element-wise creates a new object, and ideally you'd be able to avoid that by just using
mxv.